Description

The flow inside of the venturi meter is accelerated by the 21±1º angle converging cone and the flow will be measured using the differential pressure between upstream of the cone and throat. Venturi tube with machined convergent of angle of 10.5±1º may be used in accordance with ISO/TR 15377. The fluid slows down in a cone with smaller angle(7-15º) where most of the kinetic energy is converted back to pressure energy. Because of the cone and the gradual reduction in the area there is no “Vena Contracta.” The flow area is at a minimum at the throat.

Though 0.995 and 0.985 of the coefficient of discharge(Cd) are designated for machined type and welded type respectively as a standard, they can be changed significantly at the low Reynolds number. See ISO 5167-4:2003(E) Annex B.

The pressure recovery is much better for the venturi meter than for the orifice plate.